MAXIEZ Major and Medium Fault Codes (MON1/O=0/0)
TSEG2 | TSEG1 | Meaning |
---|---|---|
0, Inverter |
0, Emergency stop | IPM abnormality detected, overcurrent detected |
1, Emergency stop | IPM abnormality detected, overcurrent detected | |
2, Nearest floor stop | Overload detected, high temperature detected | |
3, Cannot start | Overload detected, high temperature detected, DC-CT abnormality | |
4, Alarm | Temperature rise detected | |
1, Frequency Converter |
0, Emergency stop | Charging abnormality detected |
1, Emergency stop | Undervoltage, overvoltage | |
3, Cannot start | Undervoltage, overvoltage | |
2, Frequency Converter Board |
3, Cannot start | Feedback frequency converter abnormality (regenerative rectifier fault) |
3, Power Supply |
1, Emergency stop | Power supply abnormality |
2, Nearest floor stop | Control power supply drop | |
3, Cannot start | Battery charging circuit, power switching circuit abnormality | |
4, Alarm | RAM backup in progress |
MAXIEZ Minor Fault Codes (MON1/0=1/0, 1/1, 1/8, 1/9)
7SEG3/2/1 | English | Meaning |
---|---|---|
001 |
SS-10C | Hardware overcurrent |
005 |
SS-GDF | Door circuit fault |
00E |
SD-TOCR | Overload operation (DC) |
00F |
SD-SLIT | MELD overload operation |
011 |
SS-LF0 | INV protection circuit operation |
012 |
SY-DESTR | IPC cancel command |
Additional Fault Codes
Code | English | Meaning |
---|---|---|
611 |
SD-32GQ | Drive software abnormality |
612 |
SC-S29 | Management software abnormality |
623 |
SW-EST2 | EST action twice |